| AGT400 Isotope Thickness Gauge |
AGT600 Laser Thickness Gauge |
AGT800 Laser Thickness Gauge |
Competitive X-ray Thickness Gauge |
|
|---|---|---|---|---|
| Purchase Price |
Low to Medium
|
Low
|
Low to Medium
|
High to Extremely High
|
| Air Gap |
2 – 12″
|
2″
|
2 – 12″
|
Varies
|
| Measured Materials |
Various Metals
|
All
|
All
|
Vary by kV
|
| Alloy Sensitivity |
Low
|
None
|
None
|
Varies
|
| Thickness Range |
.007 to .250″ steel
|
.001 to .750″ any material
|
.001 to .750″ any material
|
Varies by kV
|
| Width Range |
4 to 96″
|
1 to 36″
|
4 to 96″
|
Varies by Brand
|
| Scanning Capability |
Yes
|
No
|
Yes
|
Varies by Brand
|
| Strip Edge Proximity |
~2″
|
Configurable
|
~1/4″
|
Varies by Brand
|
| Passline Height Sensitivty |
Medium
|
Low
|
Low
|
Low
|
| Passline Angle Sensitivity |
Medium
|
Medium
|
High to Low
|
Medium
|
| Liquid on Material Sensitivity |
Low
|
High
|
High
|
Low
|
| Electronic Noise |
High
|
Extremely Low
|
Extremely Low
|
Low
|
| Response Time |
Slow
|
Fast
|
Fast
|
Fast
|
| Air Required For Installation |
No
|
Yes
|
Yes
|
Yes
|
| Water Required For Installation |
No
|
No
|
No
|
Yes
|
| S.P.C. Reporting |
Yes
|
No
|
Yes
|
Varies by Brand
|
| Data Storage |
Yes
|
No
|
Yes
|
Varies by Brand
|
| Radiation Exposure Risk |
Low
|
None
|
None
|
Medium
|
| Federal Licensing Requirements |
Yes
|
None
|
None
|
None
|
| State Licensing Requirements |
Vary by State
|
None
|
None
|
Vary by State
|
| Leak Test Requirements |
Vary by Country
|
None
|
None
|
None
|
| Terrorism Risk |
Possible
|
None
|
None
|
None
|
| Reliability |
High
|
High
|
High
|
Low
|
| Maintenance Costs |
Low
|
Low
|
Low
|
High
|
| Repair Costs |
Low
|
Low
|
Low
|
Very High
|